Tektronix DPO4032 Digital Phosphor Oscilloscope 350 MHz 2 Channels 2.5 GS/s, 10M record lenght.
Demo unit for sale. Still has more than 2 years factory warranty (probes are not part of the warranty).
* Up to 2.5 GS/s on all channels
* 10 Meg Record length on all channels
* Wave Inspector controls for unprecedented efficiency in waveform analysis
* I2C, SPI, CAN Serial triggering and analysis
* Only 5.4" Deep and 11 pounds
* USB and CompactFlash on front panel for quick and easy storage
* Plug-and-Play connectivity and analysis software solutions
* USB 2.0 device port for direct PC control using USBTMC
* Suite of advanced triggers
* e*Scope Remote viewing and control
* Interoperability with Tektronix logic analyzers
* TekVPI Probe Interface supports active, differential and current probes for automatic scaling and units
The DPO4000 Series digital phosphor oscilloscopes deliver the performance you need to visualize even your most demanding signals. Bandwidths range from 350 MHz to 1 GHz, and with all models offering a minimum of 5-times over-sampling on all channels and sin(x)/x interpolation standard, you can be confident that even the fastest transient events will be captured and displayed accurately. The standard 10 M record length on all channels enables you to capture long windows of signal activity while maintaining fine timing resolution. The DPO4000 Series offers a variety of analytical solutions including cursors, 25 automatic measurements, statistics and waveform math. Despite a tiny footprint of only 5.4" deep and light weight of 11 lbs., the DPO4000 Series offers exceptional performance, a large 10.4" XGA display and knob per channel vertical controls.
Imagine trying to efficiently use the internet if search engines didn’t exist, web browser features such as favorites didn’t exist or ISPs weren’t around. Now you know how most modern oscilloscope users feel when trying to actually use the long record length in their digital oscilloscope. The longer the record length, the longer the time window you can capture with high resolution (high sample rate). Megapoint record lengths represent thousands of screens worth of signal activity. Tools for effectively and efficiently viewing, navigating and analyzing long record length acquisitions have been sorely neglected until now.
The DPO4000 Series redefines expectations for working with long record lengths with these innovative Wave Inspector controls:
Zoom/Pan. A dedicated, two-tier knob provides intuitive control of both zooming and panning. The inner knob adjusts zoom factor or scale. The outer knob pans the zoom box across the waveform. The farther you turn the outer knob, the faster the zoom box moves. No longer do you need to navigate through multiple menus to adjust your zoom view.
Play/Pause. A dedicated play/pause button scrolls the waveform automatically while you look for anomalies or an event of interest. Playback speed and direction are controlled using the intuitive pan knob.
Search Marks. A robust waveform search feature allows you to search through your long acquisition based on user-defined criteria. All occurrences of the event are highlighted with search marks and are easily navigated to, using the front panel Previous and Next buttons. Search types include edge, pulse width, runt, logic, setup and hold, rise/fall time and I2C, SPI and CAN packet content.
Serial Triggering and Analysis
* Bus Display. Provides a higher level combined view of the individual signals that make up your bus, making it easy to identify where packets begin and end and identifying sub-packet components including address, data, identifier, and CRC.
* Serial Triggering. Trigger on packet content such as start of packet, specific addresses, specific data content, and unique identifiers on popular low-speed serial interfaces.
* Bus Decoding. Tired of having to visually inspect the waveform to count clocks, determine if each bit is a 1 or a 0, combine bits into bytes and determine the hex value? Let the oscilloscope do it for you! Once you’ve set up a bus, the oscilloscope will decode each packet on the bus, and display the value in either hex or binary in the bus waveform.
* Packet Decode Table. In addition to seeing decoded packet data on the bus waveform itself, you can view all captured packets in a tabular view much like you would see on a logic analyzer. Packets are listed consecutively with columns for each component.
* Search. Serial triggering is very useful for isolating the event of interest. With the DPO4000 Series, you can search through the acquired data for user-defined criteria including serial packet content. Each occurrence is highlighted by a search mark. Rapid navigation between marks is as simple as pressing the Prev and Next buttons on the front panel.
* DPO4AUTO. Automotive Serial Triggering and Analysis Module. Enables triggering on packet level information on CAN bus as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools and packet decode tables with timestamp information.
* DPO4EMBD. Embedded Serial Triggering and Analysis Module. Enables triggering on packet level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools and packet decode tables with timestamp information. SPI is available on four-channel models only.
The new TekVPI probe interface sets the standard for ease of use in probing. TekVPI probes feature status indicators and controls, as well as a probe menu button right on the comp box. This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe. The TekVPI interface utilizes a new probe power management architecture enabling direct attachment of current probes without requiring a separate, bulky power supply. Finally, TekVPI probes can be controlled remotely via USB, GPIB or Ethernet, enabling more versatile solutions in ATE environments.
Unprecedented USB Connectivity
The DPO4000 Series delivers an unprecedented new level of USB plug n play operation and PC connectivity. Acquiring data and measurements from the instrument is as simple as connecting a USB cable from the oscilloscope to the PC. Provided applications include National Instruments SignalExpress Tektronix Edition, OpenChoice Desktop, and Microsoft Excel and Word toolbars enabling fast and easy direct communication with your Windows PC. USB and CompactFlash ports on the front panel enable simple transfer of screenshots, instrument settings, and waveform data in the palm of your hand.
Video Design and Development Applications
Many video engineers have remained loyal to analog oscilloscopes, believing the intensity gradations on an analog display are the only way to see certain video waveform details. The DPO4000 Series' fast waveform capture rate coupled with its intensity graded view of the signal provides the same information-rich display as an analog oscilloscope, but with much more detail and all the benefits of digital scopes. With up to 1 GHz bandwidth and four inputs, the DPO4000 family provides ample performance for analog and digital video use.
National Instruments SignalExpress Tektronix Edition. A fully interactive measurement software environment optimized for the DPO4000 Series enables you to instantly acquire, generate, analyze, compare, import and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard DPO4000 Series support for acquiring, controlling, viewing and exporting your live signal data is permanently available through the software. Additional signal processing, advanced analysis, mixed signal, sweeping, limit testing and user-defined step capabilities are available for a 30-day trial period. Click here for full version >>
OpenChoice Desktop. Enables fast and easy communication between a Windows PC and the DPO4000 Series via USB or LAN. Transfer and save settings, waveforms, measurements and screen images.
TekXL and TekW Toolbars. Integrated into Microsoft Office and allow you to transfer waveforms and plot measurements using Excel and capture screen images in a Word document.
IVI Driver. Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET and MATLAB.
All models include: One P6139A 500 MHz, 10x Passive Probe per Channel, Front Cover, CompactFlash Memory Card (≥32 MB), User Manual, Documentation CD, OpenChoice Desktop Software, National Instruments SignalExpress Tektronix Edition Software, NIST Calibration Certificate, Power Cord, Accessory Bag.